POTIUS™ Residential Panel System
Description

A prefabricated panelised building system of roof, wall, intertenancy wall and floor panels for residential buildings. Panels combine LVL framing with an OSB or crossbanded LVL skin and, where required, factory-applied Heatlok HFO PU spray foam insulation. Each panel is engineered and cut to the project design, and panels can form the whole building shell or be combined with traditional framing.

Key Features
  • Roof panels: LVL H1.2 rafters at 600mm centres (typical) with an 8mm OSB3 skin, bonded and nailed, providing roof diaphragm action when panels are connected using Potius panel-to-panel and roof-to-wall details. Closed-cell PU insulation set to the R-value required
  • Wall panels: LVL8 H1.2 framing (LVL11 available for studs) with an OSB rigid air barrier on the external face. Closed-cell PU from R1.8 to R4, or R4 to R8 with a second spray; typically R3
  • Intertenancy wall panels: staggered stud construction with 90x45 LVL8 studs on 140x45 LVL plates, lined each side with 8 or 12mm OSB and 16mm GIB Fyreline®. Minimum 90mm glass wool or fibreglass cavity blanket, 8kg/m³ minimum density (for example Pink® Batts® Classic R1.8); polyester is not acceptable
  • Floor panels: LVL8 H1.2 joists at 600mm centres (typical) with a 25mm crossbanded LVL top skin (untreated) acting compositely as a stressed skin panel. Typically R2.5 PU for subfloors; H3.2 treated plywood in wet areas where specified by the building designer
  • All insulation R-values stated are for the insulation material only
  • Roof and floor thicknesses 140, 190, 240 and 300mm; wall thicknesses 90, 140 and 190mm
  • Maximum panel size 3.0m wide x 12.0m long; typical 2.4m x 6.0m
  • Options for isolated thermal frames, staggered studs and reduced nogging to limit thermal bridging; internal wrap can be added for higher airtightness
  • Standardised roof to wall, wall to floor, floor to bearer and panel to panel connection details
  • Custom engineered by Potius Chartered Professional Engineers, with fire and acoustic design support
NZ Made
NZ Made
NZ-Owned Business
NZ-Owned Business
Scope of Use

Roof, external wall, internal load-bearing wall, intertenancy wall, subfloor and mid-floor structure for houses, small dwellings, baches, townhouses, terraced housing and low-rise apartments. Suits mono pitch roofs and vaulted or raking ceilings. Engineered for the project's wind zone (NZS 3604 Low to Extra High, or specific design), earthquake zone and exposure zone, including coastal sites. Suitable on concrete or timber foundations, sloping sites and remote sites. Suits Healthy Homes and passive house projects where high insulation and airtightness are required.

Limitations on Use
  • Panels are H1.2 treated and must be kept dry during construction. Install under a dry programme and cover panels until the building is enclosed
  • The OSB wall skin is not a cladding. A compliant wall underlay, cladding system and cavity, installed by others, is required to meet E2
  • Roof underlay and roofing are installed by others over the panel and must suit the PU roof system
  • Roof and floor diaphragm capacity is project specific and confirmed by Potius design. Diaphragm action depends on panel-to-panel and roof-to-wall connections being installed as detailed
  • Do not cut, notch or penetrate panels, including the OSB skin, framing or sheathing, without Potius engineering approval. Concentrated loads and large openings in floors need Potius engineering review
  • Subfloor ventilation and ground clearance to NZS 3604 and E2 still apply
  • Intertenancy fire and acoustic performance relies on the specified build-up, including linings, fire stopping and penetration details. Do not substitute components; services penetrations must use approved fire and acoustic sealing systems
  • Intertenancy fire and acoustic compliance is confirmed for each project. Fire design requires review and certification by a fire engineer, and a project-specific acoustic review of the junction details is recommended
  • Compatible with traditional frame and truss construction, Prolam glulam and other building systems; connections and junctions detailed by Potius

Statement of Building Code Compliance
  • B1 Structure: Specifically engineered by Potius Chartered Professional Engineers using AS/NZS 1170 and NZS 3603, as an alternative solution
  • B2 Durability: H1.2 LVL treated to NZS 3602 and the untreated crossbanded LVL floor skin achieve the 50 year durability requirement for structure, and the PU insulation the 50 year requirement for elements difficult to access or replace, when installed within a weathertight building envelope. H3.2 treated plywood is used in wet areas where specified by the building designer. Compliance demonstrated as an alternative solution
  • F2 Hazardous Building Materials: Panels contain no hazardous building materials when installed
  • H1 Energy Efficiency: Insulation material R-values are based on data supplied by the manufacturer of Heatlok HFO. The construction R-value, and H1 compliance for the building, are determined by the building designer for each project

In-Service History

Potius has manufactured engineered timber floor and roof panels in Nelson since 2007, and pre-insulated wall and roof panels since 2013. The stressed skin floor panel was developed by structural engineer Gavin Robertson and prototyped over 18 months. Residential projects include Morepork Bach, Strang House (Nelson), Edmondston House, Kaiuma Bay Accommodation and Habitat for Humanity units. At Jennian Apartments, Potius intertenancy walls and mid-floor panels replaced concrete in Jennian Homes' multi-unit developments.

Other Performance Attributes
  • Factory-applied PU gives gap-free insulation fill between framing
  • Closed-cell PU has very low water absorption
  • PU does not contain plasticisers and is compatible with PVC wiring and pipes
  • Timber intertenancy walls are lighter than concrete, reducing foundation and seismic demands
  • Longer spans and lighter subfloors require fewer piles, and floor panels provide an immediate safe working platform on site
  • Heatlok HFO insulation uses recycled plastics, soy oils and a non ozone depleting blowing agent; manufacturer EPD available on request
  • Timber construction stores carbon

Documents
Insulation Map
POTIUS Details
POTIUS Brochure

3.3

For 20 years, Prolam has been a proud manufacturer of New Zealand structural laminated posts and beams.

Product Enquiries

News from Prolam

Prolam Glulam Helps Shape an Award-Winning Architect’s Low-Carbon Home
Prefabricated Timber Pavilions Challenge Conventional School Building Design
Prolam Pergolas Frame The Haven’s Bold and Beautiful Alfresco Spaces
Get a free weekly digest of essential news

New and updated architectural products, design solutions, inspiration, technical advice and more when you sign up for EBOSS.