DuPont Tyvek Supro & Supro Plus Roof Underlay
Description

DuPont™ Tyvek Supro and Supro Plus(2506B) is a self-supporting, fire retardant synthetic roof underlay, made by laminating a spun-bonded high-density polyethylene (HDPE) to a non-woven polypropylene sheet providing a strong weather resistant barrier with excellent water vapour permeability. 

Supro Plus:

The DuPont Tyvek Supro Plus (2506B) has an integrated tape system for ease of in-situ edge sealing.  

Supro Plus has all the features and benefits of DuPont Tyvek Supro with the added unique benefit of a built in adhesive tape to help provide maximum air and water protection at all overlaps. 

Key Features
  • CodeMark certified to ensure compliance with New Zealand Building Code requirements
  • Backed by a DuPont warranty
  • High Moisture Vapour Transmission Rate which allows buildings to dry out from the inside helping reduce condensation
  • Self-supporting for spans up to 1200mm
  • Non Kraft Paper based meaning it may be exposed to rainfall during installation without affecting durability or performance
  • Functional layer of 175 microns (up to seven times the thickness of other synthetics) which provides a robust, durable and 120 day UV resistant underlay to withstand job site conditions
  • No shrinkage which allows no maximum run length on installation
  • 1.5m wide roll which covers more area per sheet with less number of overlaps
  • SuproPlus has a built in adhesive tape to provide maximum protection from air and water infiltration at overlaps

 

Scope of Use
  • DuPont Tyvek Supro/Supro Plus is designed for temporary weather protection during construction and as a secondary weather barrier in service
  • Suitable for use under dark coloured roofs without support in horizontal installed applications above 3° and vertical applications above 10° roof pitches

Suitable for the following applications where roof design, ventilation and climate conditions are considered; 

  • Residential:
    • Roofing under profiled metal cladding, metal tiles, concrete tiles, clay tiles and asphalt shingles over steel or timber framing
    • Wall applications under direct fixed absorbent and non-absorbent claddings
    • Wall applications under wall cavity with absorbent and non-absorbent claddings
  • Commercial:
    • Roofing under profiled metal cladding, metal tiles, concrete tiles, clay tiles and asphalt shingles over steel or timber framing
    • Wall applications on direct fixed absorbent and non-absorbent claddings
    • Wall applications over wall cavity with absorbent and non-absorbent claddings
  • Shed and farm buildings under profiled metal roof and wall cladding direct fixed over timber or steel frames

DuPont Tyvek Supro shall be installed in accordance with New Zealand Building Code Compliance Document E2/AS1, NZMRM Roofing Code of Practice

  • Shingle lapped minimum 150mm when laid horizontally for roof pitches above 3°
  • Supported when laid vertically between 3° and 10° roof pitches or unsupported above 10°
  • Installed as to ensure water sheds to gutter
  • Laid continuously or lapped 150mm over framing. There is no limit on the length of run
  • Supported at purlin/rafter spans greater than 1200mm 
  • Secured adequately with galvanised or stainless-steel staples, clouts or purlin screws at maximum 600mm centres
  • Always laid with grey printed surface facing outwards and pulled taut under the cladding to prevent ponding of condensation
  • Taped along seams with DuPont Tyvek tape when run vertically at roof pitches between 3° and 10°. Alternatively use DuPont Tyvek Supro Plus.
  • Were installed as an air barrier, tape/seal overlaps, end laps, discontinuities and penetrations.
  • Sealed around penetrations to prevent water ingress into the roof or wall cavity
  • Use DuPont Tyvek tape to repair if ripped or torn
  • Discontinuous over the ridge where allowance for ridge venting is required
  • Not permitted to be exposed to the elements after final cladding
  • Finished 20-25mm beyond the valley or gutter edge, ensuring draining to the envelope exterior
  • Installed over gutter-flashing where there is likelihood of water ingress beyond gutter into the wall cavity

Wall Underlay:

  • DuPont Tyvek Supro/Supro Plus is suitable for use behind absorbent and non-absorbent wall cladding, direct fixed or with vented cavity

Treated Timber:

  • If installed over LOSP treated timber, ensure that timber is dry and solvent free

Condensation Management:

  • Ensure that the building envelope design and construction adhere to sound condensation management principles, minimising moisture ingress and maximising drying capabilities of wall and roof cavities. See AS 4200.2:2017 Appendix C, NZ Metal Roof and Cladding Code of Practice or ABCB Condensation in Buildings Handbook.
Limitations on Use
  • DuPont Tyvek Supro/Supro Plus must not be:
    • Used as a vapour barrier
    • Installed horizontally on purlins spacing's of greater than 1350mm for 150mm laps
    • Installed on roof pitches less than 3º
  • Do not expose the roof underlay for longer than necessary and no more than 120 days
  • Store DuPont Tyvek Supro/Supro Plus out of direct sunlight, in a clean dry environment, sheltered from the weather
  • Do not install DuPont Tyvek Supro / Pro under translucent cladding or skylights
Statement of Building Code Compliance

DuPont Tyvek Supro, when installed in accordance with the recommended guidelines will meet or contribute to meet the following provisions of NZBC:

  • NZBC Clause B2: Durability. Meets the requirement of NZBC B2/AS1 Table 1 (Building Wraps/Roof Underlay)
  • NZBC Clause E2: External Moisture. Contributes to meet these requirements for use as a roof underlay and air barrier
  • NZBC Clause F2: Hazardous Building Materials. Meets this requirement and will not present a health hazard to people according to F2.3.1

DuPont Tyvek Supro is an Alternative Solution to NZBC E2/AS1

In-Service History
  • Supro has been Installed on roofs in Europe for the past 30 years, and Supro Plus for 20 years.
  • Used on New Zealand roofs over the past 10 years
  • Backed by a DuPont warranty
Other Performance Attributes

Flammability:

  • DuPont Tyvek Supro/Supro Plush as a flammability index of less than 5 according to AS1530.2 and meets the requirements of NZS2295:2006 Amd.
B2 Durability compliant
Durability
C Protection from Fire compliant
Protection from Fire
E2 External Moisture compliant
External Moisture
E3 Internal Moisture compliant
Internal Moisture
F2 Hazardous Building Materials compliant
Hazardous Building Materials
H1 Energy Efficiency compliant
Energy Efficiency
CodeMark
CodeMark
Documents
Data Sheet
Material Safety Data Sheet
CodeMark Certificate
Environmental Product Declaration (EPD)
Installation and Operation
DuPont Tyvek Product Portfolio
Tyvek Product Guide

Tyvek building envelope solutions help make buildings more durable, comfortable, and energy efficient, and are now distributed by Pink Batts insulation in New Zealand.

Product Enquiries

News from Tyvek

Vapour Permeable Wall Underlay Keeps Interiors Dry
DuPont Tyvek Underlay Suited for Skillion Roofs
Tyvek Metal Used for Drainage and Ventilation
Get a free weekly digest of essential news

New and updated architectural products, design solutions, inspiration, technical advice and more when you sign up for EBOSS.