You are using an outdated browser version not supported by this website.
Click here to upgrade your browser

Pool Heat Pump: From 270m2 to Up to 630m2
Description

The Titanium Series Swimming Pool or Spa Heaters are part of the Performance Plus range of models. Each unit ensures a constant pool or spa temperature every time. These units are ideal for up to 630m² size pools and spa pools in the Coastal North Island or up to 580m² size pools in the Central North Island and South Island (see "Scope" for further details). Larger sizes are available, please contact Hot Water Heat Pumps for information on these. Typically, for every 1kW of electric input, users receive 5kW worth of heat. 

Key Features
  • Quiet running
  • Built in drain tray
  • Water flow switch activated 
  • Titanium tube heat exchanger
  • Ozone friendly refrigerants
  • Epoxy coated corrosion resistant evaporator coils
  • Built in refrigeration safety switches
  • Electronic reverse cycle de-ice control
  • Easy to operate electronic controller with digital display
  • TX valve for more efficient low ambient operation
  • Compressor has built in internal and external overload

Performance plus BENEFITS

  • Easy to install and operate
  • Low operating costs and high efficiency
  • Environmentally friendly
  • Durable and long life expectancy
  • Engineered and built in New Zealand
  • Automatically maintains any set temperature in all weather
NZ-Owned Business
NZ-Owned Business
Scope of Use

The heat pump most suited to each situation is determined by a number of factors; the surface area of the pool, pool use, whether the pool has a cover and the time the pool is covered, local temperature and weather conditions

For heat pump sizing for the duration of use your require, please contact Hot Water Heat Pumps.  As a general guide to heat pump requirements for an extended season of swimming from mid October to mid April:

100kW Heat Pump - 7GP100-3 & 7GP100-3v (3 Phase) 

Note: v model is taller and narrower than standard models

  • Residential Pool (up to 4 hours per day uncovered) with a surface area up to 450m2 for most of the North Island, up to 420m2 for the Central North Island and South Island.
  • School Pool (up to 6 hours per day uncovered) with a surface area up to 427m2 for most of the North Island, up to 322m2 for the Central North Island and South Island.
  • Commercial Pool (up to 12 hours per day uncovered) with a surface area of up to 290m2 for most of the North Island, up to 240m2 for the Central North Island and South Island. 

120kW Heat Pump - 7GP120-3 & 7GP120-3v (3 Phase) 

Note: v model is taller and narrower than standard models

  • Residential Pool (up to 4 hours per day uncovered) with a surface area up to 540m2 for most of the North Island, up to 500m2 for the Central North Island and South Island.
  • School Pool (up to 6 hours per day uncovered) with a surface area up to 466m2 for most of the North Island, up to 396m2 for the Central North Island and South Island.
  • Commercial Pool (up to 12 hours per day uncovered) with a surface area of up to 350m2 for most of the North Island, up to 297m2 for the Central North Island and South Island. 

140kW Heat Pump - 7GP140-3 & 7GP140-3v (3 Phase) 

Note: v model is taller and narrower than standard models

  • Residential Pool (up to 4 hours per day uncovered) with a surface area up to 630m2 for most of the North Island, up to 580m2 for the Central North Island and South Island.
  • School Pool (up to 6 hours per day uncovered) with a surface area up to 547m2 for most of the North Island, up to 448m2 for the Central North Island and South Island.
  • Commercial Pool (up to 12 hours per day uncovered) with a surface area of up to 360m2 for most of the North Island, up to 350m2 for the Central North Island and South Island. 

For Heat Pumps suitable for larger pools please contact us. 

Ideal applications

  • Swimming pool
  • Spa heating
  • Hydroponics
Other Performance Attributes

All residential heat pump pool heater models carry a comprehensive two year parts and labour warranty, including the compressor, evaporator coils, heat exchanger and refrigeration systems. The titanium tube within the heat exchanger is covered against corrosion for 30 years for residential use and 10 years for commercial use.

Heat pump water heaters are fitted with protection systems to prevent damage in the event of a malfunction. For example a flow switch to ensure the heat pump cannot operate without water flow and other refrigeration safeties. If a problem is identified, the unit automatically shuts down before damage can occur.

Documents
7GP100-3 Commercial Technical Specifications
7GP100-3v Commercial Technical Specifications
7GP120-3 Commercial Technical Specifications
7GP120-3v Commercial Technical Specifications
7GP140-3 Commercial Technical Specifications
7GP140-3v Commercial Technical Specifications
Brochure
Additional Information

Products include hot water heat pump solutions for hot water systems, swimming pool and spa heating and indoor pool ventilation.

Product Enquiries

News from Hot Water Heat Pumps

Thames Centennial's Hunt for Efficient Outdoor Pool Heating
Indoor Pool Heating and Ventilation Design for Streamline Swim Academy
Hilton Brown Swim School Reduces Greenhouse Gas Emissions
Get a free weekly digest of essential news

New and updated architectural products, design solutions, inspiration, technical advice and more when you sign up for EBOSS.