You are using an outdated browser version not supported by this website.
Click here to upgrade your browser

Equus Soprema TPO-Therm Warm Roof System
Description

The Equus Soprema Flagon TPO-Therm Warm Roof System is a light-weight, thermally insulated roofing system consisting of the Flagon TPO single layer membrane applied over a thermal insulation board and vapour barrier. A warm roof system guarantees a continuous and efficient thermal resistance (R-value) as per the New Zealand Building Code's H1 requirements. This system is designed for us on exposed flat roofs and decks.

Flagon TPO-Therm provides a UV resistant, puncture resistant membrane, that is installed with adhesive and hot air meaning a totally flameless installation for the residential and commercial industries. With an aesthetically pleasing colour of a darker grey than traditionally found in the NZ TPO market, or a sand grey with a higher solar reflectance, the system is suitable for a range or locations. This roofing system is a suitable solution for all areas of the country and can be installed over a concrete, plywood or metal substrate.

Advantages of Choosing a Warm Roof

  • Specific project design with condensation risk analysis (CRA) and wind load calculations to ensure the best system available for the buildings requirements.
  • Condensation Control – A warm roof moves the dew point to the outside of the structure, ensuring there is no condensation build up in the ceiling cavity.
  • No condensation build up negates the need for mechanical venting, causing less penetrations in the membrane.
  • Energy Cost savings are maximised with less need for heating or cooling throughout the building.
  • Creates more space within the ceiling for services.
  • Light-weight system, strong and flexible for resistance to seismic movement.
Key Features
  • BRANZ Appraised
  • Lightweight, single layer
  • Installed with adhesive and hot air meaning a totally flameless installation
  • UV resistant, puncture resistant membrane
  • Aesthetically pleasing Basalt Grey colour or Sand Grey for higher solar reflectance

Equus Soprema Technical Support

  • Project specific specifications and details
  • Condensation risk analysis for warm roof systems
  • Wind uplift study for warm roof systems
  • On-site quality assurance
  • Nationwide network of Certified Applicators
  • Warranties available
Categories
Membrane Roofing
Ranges
Decking Roofing
Scope of Use

In the opinion of BRANZ, Equus Soprema Warm Roof System, if designed, used, installed and maintained in accordance with the statements and conditions of Appraisal 1169, will meet or contribute to meeting the following provisions of the NZBC:

  • Clause B2 DURABILITY: Performance B2.3.1 (b) 15 years.
  • Performance E2.3.1 and E2.3.2.
  • Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1.
  • Clause H1 ENERGY EFFICIENCY: Performance H1.3.1 (a). Equus Soprema Warm Roof System contributes to meeting this requirement.

See BRANZ Appraisal 1169 for full information.

Limitations on Use
  • Building designers are responsible for the building design and for the incorporation of Equus Soprema Warm Roof System into their design in accordance with the declared properties and instructions of Equus Industries Ltd.
  • Must be installed by Equus Industries Ltd approved and trained installers.
Statement of Building Code Compliance

Equus Soprema Warm Roof System has been appraised for use as an insulating roof or deck on buildings within the following scope:

  • the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with regards to building height and maximum floor plan areas; and,
  • on limited access flat roofs with concrete, timber, cross-laminated timber (CLT), Strandsarking® (roofs only) or steel substrates and incorporation of the Equus Soprema Warm Roof System subject to specific structural design; and,
  • with roofs and decks constructed to drain water to gutters and drainage outlets complying with the NZBC; and,
  • with roofs and decks constructed to suitable falls (refer to Paragraphs 15.3 and 15.4); and,
  • with no integral roof gardens and no direct discharge from downpipes; and,
  • situated in NZS 3604 Wind Zones up to, and including, Extra High.

Equus Soprema Warm Roof System has also been appraised for durability and thermal performance as an insulated roofing system on buildings that are the subject of specific design with no building height restriction. 

See BRANZ Appraisal 1169 for full information.

Other Performance Attributes
  • Warranty 20 years with the correct specification and installed by an Equus Certified Applicator
  • UV resistant, puncture resistant membrane
BRANZ Appraised
BRANZ Appraised
Documents
Product Statement: Equus Soprema TPO-Therm Warm Roof System

2025

Equus Document Library
BRANZ Appraisal 1157

No. 1157 [2021]

BRANZ Appraisal 1169: Warm Roofs

No 1169 [2021] amended 2024

Equus Industries Ltd provide technical waterproofing, tanking, coating and flooring solutions for architects, engineers, property managers and contractors in the building industry.