Statement of Building Code Compliance
BlondeLine, if designed, specified, installed and maintained in accordance with bbi Wood Products technical documents, will comply with, or contribute to compliance with, the following performance provisions of the NZ Building Code:
- Clause B1 STRUCTURE: Performance B1.3.1, B1.3.2, B1.3.3 (a, b, c, f, h, j, q), B1.3.4 (d)
- Clause B2 DURABILITY: Performance B2.3.1 (c), B2.3.2
- Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1
Contribution to Compliance
- B1.3.1, B1.3.2, B1.3.3 and B1.3.4(d): Bracing ratings for 9 mm and 12 mm panels have been determined by BRANZ P21 testing at Scion, for use as an alternative solution wall bracing element in accordance with NZS 3604:2011 in internal (dry conditions) wall applications only. Panels cannot be used as a structural ceiling diaphragm under NZS 3604:2011.
- B2.3.1(c) and B2.3.2: Untreated plywood used as a wall or ceiling lining in interior dry situations meets the requirements of NZS 3602:2003, forming part of Acceptable Solution B2/AS1 when specified and used in accordance with good design and building practice. A durability period of 5 years as an internal lining applies (or other statutory time frames such as 50 or 15 years as specified by the designer or specifier), provided the specific design parameters of the project are met.
- F2.3.1: Panels are manufactured to formaldehyde emission class E0 (<0.5 mg/L) in accordance with AS/NZS 2098.11.
In-Service History
- bbi Warehouse - Hastings - Completed 2023
- Hamelink House - Hastings - Completed 2025
Other Performance Attributes
- Bracing ratings (Eucalyptus core, P21 tested at Scion 2021): 9 mm: 109 BU/m wind and 109 BU/m earthquake. 12 mm: 114 BU/m wind and 114 BU/m earthquake. Minimum wall length 1200 mm, maximum stud spacing 600 mm. Test walls used 90 x 45 MSG8 studs at 600 centres with 2 x M12 hold down bolts to testing rig. 20 bracing units = 1 kN
- Bracing ratings (UV pre-finished Poplar core, P21 tested at Scion 2021): 9 mm: 102 BU/m wind, 106 BU/m earthquake. 12 mm: 114 BU/m wind, 106 BU/m earthquake. Minimum wall length 1200 mm, maximum stud spacing 600 mm
- Formaldehyde emission rating: E0, less than 0.5 mg/L, to AS/NZS 2098.11. Eucalyptus core panels use a urea formaldehyde glue line; pre-finished Poplar core panels use an E0 glue line
- Thermal conductivity and density: Thermal conductivity 0.138 W/mK; average density 540 kg/m³. Pre-finished 9 mm panels are 5 ply at an average 19.01 kg per sheet; 12 mm panels are 7 ply at an average 23.76 kg per sheet
- Moisture content: Average between 6 and 15% when manufactured
- Warranty: 12 months limited and conditional from date of purchase against manufacturing defects. Excludes damage from improper installation, exposure to moisture, environmental conditions or misuse