Tricore
Description

An insulated roof system using a steel lining to support PIR insulation and underlay with a continuous top roof sheet avoiding end laps. A unique rail under the roof sheet creates a ventilated air space that allows any condensation to dry.

Key Features
  • Weather secure continuous top roofing sheets with no end laps or joins which rely on sealant
  • Range of Dimond roof profiles either factory run up to 30m or run on site up to 90m long
  • Either Clip fixed or screw fixed roof profiles can be used
  • Slotted roof rail to allow condensation to dry out and reduce relative humidity under roof
  • Slotted roof rail to allow shorter roof fixings and to avoid roof fasteners penetrating the insulation
  • Quality Enertherm PIR Foam insulation in a choice of thicknesses for various R values offers consistent R value
  • Insulated internal gutters can also be part of the system
  • Multi layer skylights can be fitted to achieve natural lighting as well as overall R value to the roof system
Scope of Use
  • Any roof pitch above 3 degrees in roof runs up to 90m
  • Ultimate wind loads up to 5 kPa are handled by screws or clip fixings
  • R values up to 6.35 m2 C/W

Acoustic performance of the PIR insulation carries a STC 33 Rating. Better STCs can be obtained by using an additional high density layer under the roof on top of the insulation.

The Liner sheet can take foot traffic loads of 1kN on internal purlin spans up to 3.4m and act as both a working platform and means of rapid enclosure of the building space below.

Limitations on Use
  • Roof pitches below 3 degrees would need a membrane top layer which replaces the top roof sheet and slotted roof rail
  • Corrosive environments can limit the durability of steel components
3° Minimum Roof Pitch Required
Statement of Building Code Compliance

Dimond confirm Tricore roof system will met the requirements of the NZBC for 15 years, provided it is installed and maintained in accordance to Dimond recommendations.

  • Clause B2 Durability,
  • Clause E2 External moisture as an alternative solution to AS1,
  • Clause F2 Hazardous building materials
  • Clause H1 Energy efficiency
In-Service History

The liner sheet and PIR insulation have been used by Dimond's supply partner Nuralite since 2012 without issues.

Dimond roof profiles have been used in compliance with NZ Building code for more than 20 years.

Other Performance Attributes

System Material Warranty for a period of 15 years from date of installation.

Acoustic performance of the PIR insulation carries a STC 33 Rating. Better STCs can be obtained by using an additional high density layer under the roof on top of the insulation.

B2 Durability compliant
Durability
E2 External Moisture compliant
External Moisture
F2 Hazardous Building Materials compliant
Hazardous Building Materials
H1 Energy Efficiency compliant
Energy Efficiency
Documents
Dimond Roofing & Cladding Technical Manual
Installation and Operation
Dimond Homeowners Brochure
Colour Range
CAD/PDF Details
1-1-172 DD630 Parapet
1-1-172 DD630 Parapet
1-1-172 DP955 Parapet
1-1-220 DD630 Ridge
1-1-220 DP955 Ridge
2-2-173 DD630 Barge
2-2-173 DP955 Barge
3-4-175 DD630 Eaves Box Gutter
3-4-175 DP955 Eaves Box Gutter
6-5-176 DD630 Wall Roof Junction 90 deg
6-5-176 DP955 Wall Roof Junction 90 Deg
7-6-177 DD630 Roof Wall Apex
7-6-177 DP955 Roof Wall Apex
DD630 Insulated Gutter
DD630 Skylight
DP955 Insulated Gutter
DP955 Skylight

Dimond Roofing are a manufacturer of steel roofing, cladding and rainwater products.

Product Enquiries

News from Dimond Roofing

Roof to Wall Detail with Eurotray Angle Seam
Solar-Rib Accentuates Roofline of Energy-Efficient Waiheke Home
Dimond Roofing Launches Global GreenTag
Get a free weekly digest of essential news

New and updated architectural products, design solutions, inspiration, technical advice and more when you sign up for EBOSS.