Ventilation & Drainage Batten 20mm – VB20
Description

The VENT Vented Batten is a strong, durable purlin cavity batten that is designed to ensure that unimpeded airflow is guaranteed through the roof cavity of a Skillion Roof design, enabling passive airflow around the entire building envelope.

The VB20 is designed with 4mm evenly spaced openings specifically sized to prohibit large insects gaining access but wide enough to prevent capillary action. The VB20 is easy to install and come with an adhesive underside for ease of temporary fixings to metal or timber purlins.

The VB20 should be used in conjunction with other specified VENT products. Although specifically designed as an easy to fit roof ventilation product, the VB20 can also be used on walls to create vertical or horizontal ventilation flows.

Key Features
  • Free airflow of 18,000mm² per linear metre
  • Releases hot air from roof voids and eliminates condensation
  • Ensures unimpeded airflow through skillion roof cavities
  • Recommended for any skillion roof
  • New Build or Renovation
  • Easy to install — Manufactured in 1800mm lengths for easy handling
  • Additional fixing screw length is required to accommodate 20mm thickness of the VB20
  • Insect proof — Recommended 4mm vents to prevent ingress of nesting insects
  • Manufactured in recycled plastic for affordability
  • 15 year warranty
Scope of Use

Roof Ventilation Products have been appraised for use as non-structural roof battens and vents for use with pitched and skillion roof construction on buildings within the following scope:

  • the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with regards to building height and floor plan area; and,
  • with profiled metal roof cladding; and,
  • situated in NZS 3604 Wind Zones up to, and including Extra High.

The VENT Vented Batten (VB20) is designed for use on all skillion roof designs irrespective of the roof cladding. It can be used in all climates and weather conditions.

The VENT Vented Batten will fix to the top of the roof purlins, the upper edge of the fascia and underneath the barge flashing, and is compatible with steel and timber purlins.

  • Residential skillion roofing and commercial buildings
  • Designed to ensure that unimpeded airflow through the roof cavity of a skillion roof design
  • Also designed as a purlin vent to allow airflow throughout roof area
  • New build or renovation
  • VB20 can also be used on walls to create vertical or horizontal ventilation flows 

See BRANZ Appraisal 979

Limitations on Use

The VENT Vented Batten should be used in conjunction with other VENT products to ensure a complete ventilation system:

  • VENT Over Fascia Vent (G2500N)
  • VENT Ridge Vent (RV10P) for application on purlin

Additional fixing screw length is required to accommodate 20mm thickness of the VB20.

NZS 3604 Wind Zone Extra High suitable
Extra High Wind Zone
Statement of Building Code Compliance

In the opinion of BRANZ, Roof Ventilation Products, if designed, used, installed and maintained in accordance with the statements and conditions of this Appraisal, will meet or contribute to meeting the following provisions of the NZBC:

  • Clause B1 STRUCTURE: Performance B1.3.1, B1.3.2 and B1.3.4. Roof Ventilation Products meet the requirements for loads arising from gravity loads, wind and impact [i.e. B1.3.3 (b), (h) and (j)]
  • Clause B2 DURABILITY: Performance B2.3.1 (b) 15 years and B2.3.2. Roof Ventilation Products meet these requirements
  • Clause E2 EXTERNAL MOISTURE: Performance E2.3.2. Roof Ventilation Products contribute to meeting this requirement
  • Clause E3 INTERNAL MOISTURE: Performance E3.3.1. Roof Ventilation Products contribute to meeting this requirement
  • Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. Roof Ventilation Products meet this requirement

See BRANZ Appraisal 979 (2023) for full information.

In-Service History

Passive Ventilation has been used in Canada, America, the United Kingdom and Europe for almost four decades. By introducing passive ventilation into roofs these countries have significantly reduced internal moisture and prevented what was called 'sick home syndrome'.

More recently in New Zealand, since changes to E3:AS1 1.1.4.b of the New Zealand Building Code in 2014, passive ventilation has become more widely understood and the need to ventilate the uninhabited spaces in a building has been more widely acknowledged. Industry experts BRANZ have endorsed passive ventilation as a necessity in Skillion roof types and have recommended that all roof types are passively ventilated as redundancy to eradicate internal moisture.

The NZMRM is currently revising the Metal Roofing Code of Practice to incorporate ventilation into certain roof design and strongly recommending passive ventilation in all metal roof types.  

Since the amendment of E3:AS1 hundreds of New Zealand buildings have incorporated passive ventilation into building design and application, These buildings include MOE school Reroof projects, residential new build and renovations and commercial projects. 

The VENT Ventilated Batten has been sepcified and installed on many Ministry of Education school re-roof projects throughout New Zealand.

Other Performance Attributes
  • 15 year warranty
  • Insect proof — Recommended 4mm vents to prevent ingress of nesting insects
  • Manufactured in recycled plastic 
BRANZ Appraised
BRANZ Appraised
Documents
Passive Ventilation System: Skillion Mono Roof <15°

2021

Passive Ventilation System: Skillion Roof Pitch 15-30°

2021

Product Technical Statement

Jan 2024

BRANZ Appraisal 979

979 (2023)

System Warranty

May 2023

Brochure with Brown Batts

Jan 2024

Vent Brochure with Pink Batts

Jan 2024

BRANZ Comparative Study of Corrosion Rates in Vented and Unvented Roof Cavities

2021

Video: Why Is Passive Roof Ventilation Necessary

2021

CAD/PDF Details
Deep-Trough-Longrun-Skillion-Roof-Ridge-RV10DT-+-VB20-+-VB10

Deep-Trough-Longrun-Skillion-Roof-Ridge-RV10DT-+-VB20-+-VB10

Dec 2022

Full Set of Roof Drawings

Full Set of Roof Drawings

Dec 2022

Steel Longrun Any Pitch - Skillion Roof No Eave - G2500N + VB20 + VB10 + G1275

Steel Longrun Any Pitch - Skillion Roof No Eave - G2500N + VB20 + VB10 + G1275

Dec 2022

Steel Longrun Any Pitch - Skillion Roof With Eave - G2500N + VB20 + VB10 + G1275

Steel Longrun Any Pitch - Skillion Roof With Eave - G2500N + VB20 + VB10 + G1275

Dec 2022

Steel-Longrun-Any-Pitch-Box-Gutter-VB20-+-VB10-+-G1275

Steel-Longrun-Any-Pitch-Box-Gutter-VB20-+-VB10-+-G1275

Dec 2022

Steel-Longrun-Skillion-Roof-Apron-RV10Phalf-+-VB20-+-VB10

Steel-Longrun-Skillion-Roof-Apron-RV10Phalf-+-VB20-+-VB10

Dec 2022

Steel-Longrun-Skillion-Roof-Ridge-Barge-RV10Phalf-+-VB20-+-VB10

Steel-Longrun-Skillion-Roof-Ridge-Barge-RV10Phalf-+-VB20-+-VB10

Dec 2022

VENT provide complete passive ventilation systems that ensure healthy homes free from internal moisture and condensation.

Product Enquiries

News from VENT

VENT Ridge Vents Now Even Easier to Specify and Install
Why Specify the VB20 Ventilated Batten?
A Tested Solution for Ventilating Roofs and Preventing Heat Loss
Get a free weekly digest of essential news